This is the compact version of a simple carrier for Allegro’s CT433-HSWF30DR TMR-based, electrically isolated current sensor that is optimized for high dV/dt applications and offers a high 1 MHz bandwidth with low noise. The typical primary current path resistance of the sensor IC is 1 mΩ.

Part Prefix    Part Suffix     Range                            Supply Voltage     Sensitivity  Zero Point  Size     PCB layers

CT433              30DR      0-30 A (unidirectional)     3.0 V to 3.6 V      66.7 mV/A      0.65 V             0.8″×1.1″     2

Overview:

We are offering these breakout boards with support from Allegro Microsystems as an easy way to use or evaluate their CT432/CT433 tunneling magnetoresistance (TMR), electrically isolated, high-bandwidth current sensors that are optimized for high dV/dt applications; we therefore recommend careful reading of the applicable CT432 datasheet or CT433 datasheet before using this product. The following list details some of the sensors’ key features:


  • CT432/CT433 sensors use Allegro’s patented XtremeSense™ TMR (tunneling magnetoresistance) technology for high accuracy, high bandwidth, electrically isolated current measurements.
  • Sensor can be inserted anywhere along the current path and be used in applications that require electrical isolation.
  • 1 mΩ primary current path resistance in the sensor IC, and the PCB is made with 2-layer (compact versions under 50A), 4-layer (compact versions 50A and up), or 6-layer (large versions) 2-oz copper, so very little power is lost in the module.
  • TMR sensing rejects common-mode fields, so the orientation of the sensor relative to uniform external magnetic fields (e.g. the Earth’s magnetic field) has less effect on the measurement.
  • Optimized for high dV/dt applications, allowing the sensor to be used in switching applications.
  • High-bandwidth 1 MHz analog output voltage proportional to AC or DC currents.
  • Typical 300 ns response time.
  • Output is not ratiometric (i.e. the zero point and sensitivity are independent of the actual supply voltage), which provides immunity from noisy supplies.
  • Optional overcurrent fault output indicates when the current magnitude exceeds 110% of the maximum linear sensing range.
  • Operating temperature range of -40°C to 125°C.
  • Carrier boards, available in compact and large sizes, offer a variety of ways to insert it into the current path along with 0.1″-pitch (breadboard-compatible) power, ground, and output pins.
  • 3.3V (CT433) and 5V (CT432) versions available.
  • The connection points are labeled on the silkscreen, which is on the bottom side of the compact versions and on both sides of the large versions. The bottom silkscreen also shows the direction that is interpreted as positive current flow via the +i arrow.

Details for item #5317

      

This compact carrier features the CT433-HSWF30DR, which is intended for nominal 3.3 V operation and is designed for unidirectional input current from 0 A to 30 A. This version can be visually distinguished from the other versions by the part number printed on the sensor IC, as shown in the left picture above (the bottom silkscreen also has a blank white box that can be used for adding customized identifying markings).

Part Prefix   Part Suffix   Range                  Supply Voltage         Sensitivity       Zero Point Size          PCB layers

CT433        30DR   0-30 A (unidirectional)       3.0 V to 3.6 V         66.7 mV/A        0.65 V      0.8″×1.1″           2

Using the sensor

This sensor has five required connections: the input current (IP+ and IP-), logic power (VCC and GND), and the sensor output (VOUT).

The sensor requires a supply voltage of 3.0 V to 3.6 V to be connected across the VCC and GND pads, which are labeled on the bottom silkscreen. The sensor outputs an analog voltage on VOUT that has a zero point at 0.65 V and increases by 66.7 mV per amp of input current:

VOUT=0.65V+0.0667VAIP

The output is not ratiometric, so the zero point and sensitivity are independent of the actual supply voltage.

The optional FLT pin is normally at VCC and is pulled low when the IP current magnitude exceeds 110% of the maximum sensing range. This pin only asserts while the fault condition is present (it is not latched).

Note: The datasheet warns that using the FLT (TEST) pin as a fault output rather than grounding it will reduce the sensor’s immunity to high dV/dt events. If you do not need the fault feature, you can externally connect this pin to ground. Alternatively, we have the ability to custom-assemble these boards with this pin grounded (which would also disable the fault feature). If you are interested in customization, please contact us.

Making connections to the board

You can insert the board into your current path in a variety of ways. For typical high-current applications, you can solder wires directly to the through-holes that best match your wires, or you can use solderless ring terminal connectors. The largest through-holes are big enough for 10 AWG wires or #6 or M3.5 screws, and the second-largest through-holes (and mounting holes) are sized for 14 AWG wires or #2 or M2 screws. Holes with 0.1″, 3.5 mm, and 5 mm spacing are also available as shown in the diagram above for connecting male header pins or terminal blocks, but please note that these connection options are generally not suitable for high currents and could limit the usable range of the sensor. Examples of different kinds of connections are shown in the pictures below.

   

   

The FLT, VOUT, VCC, and GND pins work with 0.1″-pitch header pins and are compatible with standard solderless breadboards

Warning: This product is intended for use below 30 V. Working with higher voltages can be extremely dangerous and should only be attempted by qualified individuals with appropriate equipment and experience.

Schematic and dimension diagrams

CT432/CT433 TMR Current Sensor Carrier schematic diagram.

The dimension diagram is available as a downloadable PDF (436k pdf).

Real-world power dissipation considerations

Thermal image of a high-current test of a Pololu current sensor carrier (not necessarily this product).

Depending on the version, the CT432 and CT433 can measure up to ±70 A. However, the sensor chip will typically overheat at lower currents. In our tests, we found that our 2-layer CT432/CT433 compact carrier board (cs07a) could conduct about 45 A continuously, and the 4-layer compact carrier board (cs07b) could conduct about 50 A continuously, without reaching the thermal limit for the IC. (Sensors with ranges under 45 A use the cs07a board while sensors with ranges over 45 A use the cs07b board.) Our tests were conducted at approximately 25°C ambient temperature with no forced air flow.

The actual current you can pass through the sensor will depend on how well you can keep it cool. The carrier’s printed circuit board is designed to help with this by drawing heat out of the sensor chip. Solid connections to the current path pins (such as with thick soldered wires or large, tightly-secured lugs) can also help reduce heat build-up in the sensor and carrier board.

Warning: Exceeding temperature or current limits can cause permanent damage to the sensor. If you are measuring an average continuous current greater than 30 A, we strongly recommend that you monitor the sensor’s temperature and look into additional cooling if necessary.

This product can get hot enough to burn you long before the chip overheats. Take care when handling this product and other components connected to it.

Package Includes:

  • 1 x Pololu 5317 CT433-HSWF30DR TMR Current Sensor Compact Carrier 0A to 30A, 3.3V

Write a review

Please login or register to review

Pololu 5317 CT433-HSWF30DR TMR Current Sensor Compact Carrier 0A to 30A, 3.3V

  • Brand: Pololu
  • Product Code:NR-Pololu-5317-CT433-HSWF30DR
  • Reward Points:7
  • Availability:In Stock
  • रo 761.00

  • Price in reward points:761

  • 19 or more रo 755.00
  • 37 or more रo 749.00
  • 93 or more रo 743.00
  • 187 or more रo 737.00

Related Products

Pololu 5313 CT433-HSWF50MR TMR Current Sensor Compact Carrier -50A to +50A, 3.3V

Pololu 5313 CT433-HSWF50MR TMR Current Sensor Compact Carrier -50A to +50A, 3.3V

This is the compact version of a simple carrier for Allegro’s CT433-HSWF50MR TMR-based, electrically..

रo 889.00

Pololu 5335 CT433-HSWF70MR TMR Current Sensor Large Carrier -70A to +70A, 3.3V

Pololu 5335 CT433-HSWF70MR TMR Current Sensor Large Carrier -70A to +70A, 3.3V

This is the large version of a simple carrier for Allegro’s CT433-HSWF70MR TMR-based, electrically i..

रo 1,157.00

Pololu 5315 CT433-HSWF70MR TMR Current Sensor Compact Carrier -70A to +70A, 3.3V

Pololu 5315 CT433-HSWF70MR TMR Current Sensor Compact Carrier -70A to +70A, 3.3V

This is the compact version of a simple carrier for Allegro’s CT433-HSWF70MR TMR-based, electrically..

रo 889.00

Tags: Pololu, CT433, HSWF30DR, TMR, Current, Sensor

The product is currently Out-of-Stock. Enter your email address below and we will notify you as soon as the product is available.

Name
Email
Phone
Comments