The waveform capture rate of DPO6000/MPO6000 Fluorescent oscilloscope is up to 400,000 FPS.It has 256 grade color and color temperature display.Standard equipped with up to 16 kinds of trigger functions, 5 kinds of serial decoding functions.
 
Features:
  • Six in one oscilloscope:4 channels oscilloscope+16 channels logic analyzer+2 channels waveform generator+digital voltmeter+serial protocol analyzer+FFT spectral analysis.
  • 60 000 wfms/s (dots display)/400,000 wfms/s (dots display quick acquisition mode)waveform capture rate.
  • Segmented acquisition function,support to capture up to 80,000 sections.256 grade color display.
  • Up to 16 kinds of trigger functions, including 5 kinds of protocol triggers.Supply 5 serial decoding option.
  • 1 GSa/s real-time sample rate of the analog channels; 64 Mpts standardmemory depth.
  • 2-channe signal source,13 kinds of waveforms inside,4 sets of arbitrary waveforms,200M sample rate,8Kpts waveform length.
  • 1 GSa/s real-time sample rate of the digital channels.
  • 200 MHz, 100 MHz and 80 MHz analog channel bandwidth.
  • Low base noise, 500uV/div to 10 V/div ultra-wide vertical dynamic range.
  • 7 inch WVGA capacitive touch screen,(800*480) TFT , with ultra-wide screen, vivid picture, lowpower consumption and long service life.
  • Auto measurement of 42 kinds of waveform parameters (with statistics).
  • Bode diagram function(the oscilloscopes with signal source function can use).
  • Multiple waveform math operation functions【MATH】.Event search function.
  • Standard interfaces: USB Device, USB Host, LAN,Optional interfaces: HDMI ,UART
  • Conform to LXI CORE 2011 DEVICE class instrument standards; enable quick,economic and efficient creation and reconfiguration of test system.Supports remote command control.
Specifications:
 
Acquisition Real-time sample rate 1 GSa/s(single channel) 500 MSa/s(two channels)
250 MSa/s(three/four channels);
Note:digital channel 12,34 open at the same time,it is considered as one channel
Peak detection Analog channel 4ns
Note:digital channels don’t support
Average mode Analog channel
All channels reach N time samples at the same time,N can be selected from  2, 4, 8, 16, 32, 64, 128, 256, 512 and 1024.
Note:digital channels don’t support
High resolution Up to 12bit
Note:digital channels don’t support
Minimum test pulse width 8ns
Memory depth Single channel 64M
Two channels 32M
Three,four channels 16M
Input Channel quantity 4 analog channels
Note:data channels can’t be opened
3 analog channels
Note:digital channel LA1/LA2/LA3/LA4/LA1LA2/LA3LA4
2 analog channels
1 analog channel
0 analog channel
Note:digital channels infinitize
Input coupling DC, AC or GND
Note:digital channels don’t support
Input impedance,DC coupling Analog channel
25pF±3 pF,1MΩ±2%
Digital channel
(300KΩ±2%) ,(8 pF±3 pF)
Supported probe attenuation  factor Analog channel 1X, 10X, 100X, 1000X
Voltage classes 300V CAT II
Maximum input voltage Analog channel 300VRMS (10X)
Digital channel -25V~25V
Horizontal Waveform interpolation (sin x)/x
Maximum record length Single channel maximum 64M
Two channels maximum 32M
three/four channels maximum 16M
Horizontal scale range DSO6084 DSO6104
2ns/div~100s/div  1, 2, 5 step by step
Time base mode Y-T、X-Y、Roll 
X-Y number Channel 1,2 1 XY channel、channel3 4 1 XY channel
Zero offset ±0.5 div× minimum time base gear
Sample Rate ±25ppm
Delay Time Accuracy
Clock drifting ≤±5 ppm/year
Delta Time Measurement single,“acquisition”mode
Accuracy
(Full Bandwidth) ±(1 sample interval+100ppm×reading+0.6ns)
>16 times averages
±(1 sample interval+100ppm×reading+0.4ns)
Sample interval=sec/div÷200
Bandwidth reduced to 6MHz when using a 1X probe
Note: 
Vertical Bandwidth(-3db) DPO6084 DPO6104 DPO6204
80MHz 100MHz 200MHz
Vertical resolution
Analog channel 8bit
Digital channel 1bit
Vertical scale range nput BNC position is 500μV/div~10V/div
Position range 500μV/div to 120mV/div,±1V
122mV/div to 1.2V/div,±10V
1.22V/div to 10V/div,±50V
Optional analog bandwidth limitation Typical 20MHz
Bass response(-3db In BNC position is≤10Hz
Rising time in BNC position,typical DPO6084 DPO6104 DPO6204
Rising time in BNC position,typical ≤4.4ns ≤3.5ns ≤1.8ns
Vertical gain accuracy
In “normal” or “average” acquisition mode,the accuracy of 10V/div to 10mV/div is ±3%
In “normal” or “average” acquisition mode,the accuracy of 5mV/div to 500uV/div is ±4%.
DC offset accuracy ±0.1 div±2 mV±1% offset value
The isolation of channels   DC maximum bandwidth:>40 dB

 

Documents:

Package Includes:

  • 1 x Hantek DPO6004B(C) / MPO6004D Series DPO6084 / DPO6104 / DPO6204 Oscilloscope
Oscilloscope Specifications
Sample Rate 1 GSa/s (single channel, 500 MSa/s (two channels), 250 MSa/s (three/four channels)
Display Type 7"TFT diagonal liquid crystal, dot, vector
Bandwidth 80MHz, 100MHz, 200MHz
Resolution 800(horizontal)*480(vertical)pixels
Electrical Specifications
Output Voltage typical about 2Vpp input≥1MΩ load
Output Power Power Supply: 100-120VACRMS(±10%),45Hz to 440Hz,CATⅡ, 120-240VACRMS(±10%),45Hz to 66Hz,CATⅡ
Maximum Operating Temperature 0~50 °C (32~122 °F)
Physical Attributes
Weight 3900g
Size 318 x 140 x 150mm(length x width x height)

Write a review

Please login or register to review

Hantek DPO6004B/MPO6004D Series DPO6084 / DPO6104 / DPO6204 Oscilloscope

  • Brand: Hantek
  • Product Code:HTK-DPO6004B-Scope
  • Reward Points:434
  • Availability:Out Of Stock
  • रo 42,774.00

  • Price in reward points:43470

  • 2 or more रo 42,427.00
  • 5 or more रo 42,079.00

Available Options


Related Products

Hantek DSO2000 Series DSO2D15 / DSO2D10 Oscilloscope with Waveform generator

Hantek DSO2000 Series DSO2D15 / DSO2D10 Oscilloscope with Waveform generator

Hantek DSO2000 Series Oscilloscope is a Cost-effective economy oscilloscope, 150MHz Bandwidth, 1GSa/..

रo 25,334.00

Tags: Hantek, Oscilloscope

The product is currently Out-of-Stock. Enter your email address below and we will notify you as soon as the product is available.

Name
Email
Phone
Comments